Animation Your nose works as a kind of heat-recovery ventilation system. When you breathe out (1), your nasal passages are warmed by heat from the outgoing air (2). When you breathe in, the cold incoming air picks up some of this heat (3), which would otherwise have been wasted. As a child, you might have learned that it's better to breathe
DaikinAir conditioning FDXM60F9 RZAG60A Slim Ducted Heat pump 6Kw/20000Btu A+ R32 240V~50Hz. ÂŁ2,053.20. ÂŁ1,711.00 ex. VAT. Daikin Air conditioning FNA25A9 Concealed Chassis Inverter Heat pump 2.5Kw/9000Btu A+ R32 240V~50Hz. ÂŁ1,257.98.
PureAir DAIKIN 'Fresh' Air Our innovative ventilation solutions can remove polluted air indoors and enter air from outside through filters, so you can enjoy fresh air indoors. Ventilation Filter PM2.5 and save energy when ventilation. *With PM2.5 Filtration Unit. Can be reinstalled. *The process can be consulted with a Daikin technician
HeatReclaim Ventilation The Daikin heat recovery ventilation system modulates the temperature and humidity of incoming fresh air to match indoor conditions. A balance is thus achieved between indoor and outdoor ambients, enabling the cooling or heating load placed on the air conditioning system to be reduced significantly.
TheDaikin HRV (Heat Reclaim Ventilation) recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. This also reduces the load on the air conditioning system and conserves energy.
hRV- hEAT REcLAIM VENTILATION hrv helps to create a high quality indoor environment the Daikin HRv (Heat Reclaim ventilation) unit recovers heat energy lost through ventilation and maintains a comfortable and clean indoor environment without changes in room temperature. this also reduces the load on the air conditioning system and saves energy.
Daikinventilation and air purification Fresh air is vital to our quality of life and well being. But as buildings become more airtight, fresh air circulation is much reduced. Heat reclaim ventilation Proper ventilation is a key component of climate control in buildings, offices and shops. n its basic function, it ensures a flow of i
2YHfks. Product categoryVRV Air Conditioner›Heat Reclaim VentilationModel HRV VAM250GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVESpecificationMODELVAM250GJVEVAM500GJVEVAM650GJVEVAM800GJVEVAM1000GJVEVAM1500GJVEVAM2000GJVEPower Supply1-phase, 220-240 V/ 220 V, 50 HzTemp. ExchangeEf ciency50/60 HzUltra-High%75/7574/7475/7572/7278/7872/7277/77High75/7574/7475/7572/7278/7872/7277/77Low79/7980/ ciency50/60 HzFor HeatingUltra-High%71/7267/ CoolingUltra-High%63/6355/5561/6161/6164/6461/6162/62High63/6355/5561/6161/6164/6461/6162/62Low66/6659/ HzHeatExchangeModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Bypass ModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Sound Level 50/60 HzHeat ExchangeModeUltra-HighdBA27-29/ ModeUltra-HighdBA steel plateInsulation MaterialSelf-extinguishable polyurethane foamDimensions HXWXDmm278X810X551306X879X800338X973X832387X1,111X832387X1,111X1,214785X1,619X832785X1,619X1,214Machine Weighkg2432455567129157Heat Exchange SystemAir to air cross ow total heat Sensible heat+latent heat exchangeHeat Exchange Element MaterialSpecially processed non-ammable paperAir FilterMultidirectional brous eecesFanTypeSirocco fanAir ow Rate50/60 HzUltra-Highm3/h250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000High250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000Low155/155320/295500/470700/670860/8401,320/1,2601,720/1,580External Static Pressure50/60 HzUltra-HighPa70/96105/15085/125133/170168/192112/150116/ Duct Diametermmø150ø 200ø 250ø 350Unit ambient condition-15°C–50°CDB, 80%RH or lessAS A PART OF CONTINOUS DEVELOPMENT AND UPGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE/SPECIFICATION MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE.
Daikin Advantage Improved Air Quality A steady inflow of fresh, conditioned air improves air quality of indoor settings. Energy Efficiency Energy recovery between supply air and exhaust air eliminates waste to realize efficient ventilation. Flexible Installation Daikin’s unique modular system enables each unit to be tailor-fitted to the exact dimensions required. Product Lineup Refreshes stale indoor air with fresh outdoor air. Processes outdoor air to bring it near temperature of indoor air and distributes the air throughout the room. Indoor humidity is appropriately controlled by humidification and/or dehumidification. Outdoor-Air Processing Unit Supplying outdoor air at the same temperature of the room maintains comfort and lessens heat load caused by ventilation. * Can be connected only to VRV Heat Reclaim Ventilator Daikin’s unique heat exchange element realizes efficient heat exchange between supply air and exhaust air. High external static pressure enables flexible installation. Heat Reclaim Ventilator with DX-Coil A temperature adjustment function has been added to the Heat Reclaim Ventilator to better maintain comfort and lessen heat load caused by ventilation. * Can be connected only to VRV DESICA*:Heat Pump Desiccant Humidity Control Outdoor-Air Unit The DESICA permits individual control of humidity and temperature, by the hybrid DESICA element which contains a water absorption material and a heat exchanger, with lower energy consumption compared to conventional humidity control devices according to Daikin tests. * DESICA is a Daikin registered trademark in Japan. Technology Heat Exchange Element The thin film material allows only small water molecules moisture to penetrate while blocking out larger molecules such as CO2 . This eliminates waste by preventing the heat and moisture of the conditioned air from escaping outdoors and promotes efficient ventilation using less energy. Learn More Daikin's Unique Heat Pump Desiccant The heat pump desiccant integrates the heat exchanger and desiccant element to enable highly-efficient dehumidification and humidification with no need to supply or drain water. Learn More Wired Remote Controller Stylish Remote Controller Sleek stylish design DAIKIN APP for Installer simplifies the advanced settings such as field settings Useful administration / Shorter and Easier installation Stylish Remote Controller Navigation Remote Controller Operation is easy and smooth, just follow the indication on the remote controller Weekly schedule can be set 5 actions per day for each day of the week Circulation airflow, a function for the latest cassette type can be set Simplified Remote Controller Simple operation by using only six buttons, and users have direct access to basic functions Intuitive design by using pictograms enables user-friendly interface Overseas guests at hotels understand functions without having to know a foreign languages Case Study Case Study Visit the Daikin Global Case Studies page for detailed examples of installations Learn More After Sales Service A global support system delivers timely solutions to all needs. Learn More Preventive Maintenance Service AVAILABILITY The products or features on this page may not be available in your region. Please visit your local website for details on the products and features available in your region.
VAM-HVE VAM-HVE Heat Reclaim Ventilator Daikin also offers heat reclaim ventilator systems; our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range -15 to 50°C. These units provide high enthalpy efficiency due to the greatly enhanced performance of the thin film element. Furthermore, ESP* of up to 235Pa offers greater design flexibility to your air conditioning solution. Other features include Night Purge Operation night time free-cooling, interlocked operation with VRV Cassette presence sensor and optional CO2, indoor & outdoor humidity sensors for optimal operation. By incorporating heat reclaim ventilators into your air conditioning design, heat loads can be reduced and your plan size can be better optimised. *Max ESP varies from 130 Pa to 235 Pa depending on the model class Download Brochure All Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions. Technical Specifications Available Options System Reverse Cycle Capacities Indoor Type Heat Reclaim Ventilator Power Supply Refrigerant VAM-HVE Flyer Our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range. Furthermore, improved external static pressures offer greater design flexibility to support variety of duct layouts. Send the brochure to me. Enter your email below to receive the brochure link in your inbox
Product Highlights Product Range Capacities View AR View 360 DX coil cooling capacity Airflow rate 500-950 m3 /h Daikin’s HRV Heat Reclaim Ventilation recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. Equipped with a heat reclaim ventilator and a heat exchanger DX coil, VKM series is capable of minimizing room temperature fluctuations. VKM series maintains comfortable indoor air quality IAQ by adding fresh outdoor air having nearly the same temperature and humidity conditions as the indoor air. Thus, VKM ensures optimum comfort and further reduces air conditioning load. VKM – How It Works The fresh air is supplied to the office by air discharge grills connected to the VKM Supply Air duct. Heat Reclaim Ventilator + Heat Exchanger → Comfortable Air Supply Equipped with a heat reclaim ventilator and a heat exchanger, the new VKM series minimizes room temperature fluctuations. A Compact Unit Packed with Daikin’s Cutting-Edge Technologies. Air Conditioning and Outdoor Air Processing Can be Accomplished Using a Single System. When the VKM series units are connected, the total connection capacity index must be 50% to 130% of the capacity index of the outdoor units. Filtration Unit Option Removes particulate matter present in the outdoor air, as well as sulfur oxides and nitrogen oxides, providing clean fresh air to the indoor ambient. • filter Removes 99% or more of μm particulate matter. • Activated Carbon filter Removes sulfur oxides and nitrogen oxides Double-layered efficient filtration filters are double-layered. filters are double-layered. 1. The front filter effectively remove large particles. 2. The filter layer contains a large amount of static electricity to capture particulate matter effectively. Electrostatic Dust Collection Filter More Efficient and Longer Lasting Effect The filter layer contains a large amount of static electricity to capture particulate matter effectively, including those smaller than the grid mesh. The filter is difficult to be blocked by particles and has good ventilation and long life span. CO2 Sensor Optional Kit Connection for VAM / VKM Series The CO2 sensor controls airflow so that it best matches the changes of CO2 level in the room. This prevents energy losses from over-ventilation while maintaining indoor air quality with optional CO2 sensor. Tech specs Specifications ModelVKM50GCVEVKM80GCVEVKM100GCVE Power Consumption Heat Exchange modeW 270/230/170390/335/220440/370/260 Power Consumption Bypass modeW305/260/200390/335/220440/370/260 External static Pressure Pa210/170/140220/180/125170/120/90 Airflow rate m3/h500/500/440750/750/640950/950/820 Sound level Heat Exchange modedB43/ Sound level Bypass modedB43/41/ Temp exchange efficiency %76/76/ Enthalpy exchange efficiency %64/64/6766/66/6862/62/66 DX-coil Capacity kW Dimensions H x W x D387x1764x832387x1764x1214387x1764x1214 Machine weight kg92113115 You are now leaving Daikin Malaysia Once you link to another web site, you are subject to the terms and conditions of that web site, including but not limited to its privacy policy. CANCEL CONTINUE
daikin heat reclaim ventilator